6DMA
DHD15_closed
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.2.1 |
Synchrotron site | ALS |
Beamline | 8.2.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-10-27 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.999972 |
Spacegroup name | P 32 |
Unit cell lengths | 57.615, 57.615, 130.861 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 39.676 - 3.363 |
R-factor | 0.2962 |
Rwork | 0.292 |
R-free | 0.33320 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | Computational design model |
RMSD bond length | 0.002 |
RMSD bond angle | 0.359 |
Data reduction software | HKL-2000 (715) |
Data scaling software | HKL-2000 (715) |
Phasing software | PHASER |
Refinement software | PHENIX ((dev_3084: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 100.000 | 3.410 |
High resolution limit [Å] | 3.350 | 3.350 |
Rmerge | 0.131 | 1.745 |
Rmeas | 0.142 | 1.892 |
Rpim | 0.053 | 0.721 |
Number of reflections | 6816 | 338 |
<I/σ(I)> | 13.82 | 0.88 |
Completeness [%] | 98.4 | 96 |
Redundancy | 6.5 | 6.2 |
CC(1/2) | 0.337 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 290.15 | 0.1M imidazole pH 7.0, 25% (v/v) PEG 550 MME |