mouse TCR I.29 in complex with IAg7-p8E9E6ss

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]100
Detector technologyPIXEL
Collection date2014-04-23
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.9790
Spacegroup nameP 63
Unit cell lengths269.518, 269.518, 45.639
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution50.010 - 3.100
R-factor0.24197
Rwork0.240
R-free0.28515
RMSD bond length0.017
RMSD bond angle2.096
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0135)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.300
High resolution limit [Å]3.1003.100
Number of reflections32259
<I/σ(I)>24.4
Completeness [%]99.7
Redundancy6.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29812% PEG 20000, 100mM bicine pH9.0, 20% ethylene glycol