6DAT
ETS1 in complex with synthetic SRR mimic
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL9-2 |
| Synchrotron site | SSRL |
| Beamline | BL9-2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-01-15 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97946 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 89.111, 89.111, 215.700 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 39.188 - 2.350 |
| R-factor | 0.234759949156 |
| Rwork | 0.233 |
| R-free | 0.26801 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6da1 |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.506 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER (2.8.0) |
| Refinement software | PHENIX (1.12_2829) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 39.190 | 2.430 |
| High resolution limit [Å] | 2.350 | 2.350 |
| Rmerge | 0.133 | 1.898 |
| Rpim | 0.038 | 0.550 |
| Number of reflections | 37109 | 8714 |
| <I/σ(I)> | 12.8 | |
| Completeness [%] | 99.8 | |
| Redundancy | 13 | |
| CC(1/2) | 0.999 | 0.938 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 277.15 | MES, PEG 3350, lithium sulfate |