Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6D48

Cell Surface Receptor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2013-11-17
DetectorADSC QUANTUM 315r
Wavelength(s)0.9537
Spacegroup nameP 1 21 1
Unit cell lengths60.801, 41.543, 107.498
Unit cell angles90.00, 96.55, 90.00
Refinement procedure
Resolution35.599 - 1.776
R-factor0.1774
Rwork0.176
R-free0.21220
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1nko
RMSD bond length0.010
RMSD bond angle0.979
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX ((1.11.1-2575_1496: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.4801.810
High resolution limit [Å]1.7761.776
Rmerge0.0440.391
Rmeas0.0520.464
Rpim0.0280.246
Number of reflections512512673
<I/σ(I)>14.73.1
Completeness [%]98.590.3
Redundancy3.43.2
CC(1/2)0.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.529325% PEG 4000 100 mM Tris-HCl pH 8.5 10% Glycerol