Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6CFX

Bosea sp GapR solved in the presence of DNA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]273
Detector technologyPIXEL
Collection date2017-03-23
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths51.328, 44.483, 107.051
Unit cell angles90.00, 101.82, 90.00
Refinement procedure
Resolution50.240 - 2.000
R-factor0.2001
Rwork0.199
R-free0.22200
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6cg8
RMSD bond length0.003
RMSD bond angle0.504
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwarePHENIX (1.6.4_486)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.2402.110
High resolution limit [Å]2.0002.000
Rmeas0.0720.017
Rpim0.0420.011
Number of reflections296761921
<I/σ(I)>10.13.9
Completeness [%]92.069.1
Redundancy2.52
CC(1/2)0.9940.975
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP298ammonium sulphate, MES buffer pH 6.5

219140

PDB entries from 2024-05-01