Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6C9T

Transcriptional repressor, CouR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-G
Synchrotron siteAPS
Beamline21-ID-G
Temperature [K]100
Detector technologyCCD
Collection date2014-04-14
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.97857
Spacegroup nameP 41
Unit cell lengths59.008, 59.008, 108.402
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution59.010 - 2.070
R-factor0.27508
Rwork0.272
R-free0.33441
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6c2s
RMSD bond length0.012
RMSD bond angle1.707
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0189)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]59.0102.108
High resolution limit [Å]2.0732.073
Rmerge0.0660.946
Rmeas0.0701.007
Rpim0.0240.343
Number of reflections22136
<I/σ(I)>212.4
Completeness [%]98.3100
Redundancy8.58.6
CC(1/2)0.9990.850
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP728260% Tacsimate (v/v) pH 7.0

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon