6BVZ
Importin alpha 3 in cargo free state
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-04-13 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9537 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 47.118, 53.229, 91.309 |
Unit cell angles | 90.00, 92.86, 90.00 |
Refinement procedure
Resolution | 19.814 - 2.300 |
R-factor | 0.251 |
Rwork | 0.250 |
R-free | 0.26850 |
RMSD bond length | 0.005 |
RMSD bond angle | 1.029 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.814 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Rpim | 0.086 | 0.304 |
Number of reflections | 19290 | 1942 |
<I/σ(I)> | 11.3 | 1.8 |
Completeness [%] | 95.0 | 98.2 |
Redundancy | 5.5 | 6.2 |
CC(1/2) | 0.977 | 0.785 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 0.2 M sodium nitrate, 0.1 M bis-tris propane pH 6.5, 25% w/v PEG3350 |