Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6B98

PDE2 in complex with compound 1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2012-07-21
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.0000
Spacegroup nameP 21 21 21
Unit cell lengths72.034, 94.186, 102.526
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.090 - 1.970
R-factor0.202
Rwork0.199
R-free0.24000
RMSD bond length0.010
RMSD bond angle1.020
Data reduction softwareXDS
Data scaling softwareautoPROC
Refinement softwareBUSTER (2.11.6)
Data quality characteristics
 Overall
Low resolution limit [Å]47.090
High resolution limit [Å]1.970
Number of reflections50203
<I/σ(I)>17.6
Completeness [%]99.9
Redundancy6.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29312% PEG8000, 0.1M Hepes pH7.5, 1mM TCEP

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon