Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6AMG

cyt P460 of Nitrosomonas sp. AL212

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2017-04-21
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.979100
Spacegroup nameP 21 21 21
Unit cell lengths47.267, 80.138, 108.962
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution64.558 - 1.450
R-factor0.1417
Rwork0.141
R-free0.15750
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2je2
RMSD bond length0.028
RMSD bond angle2.348
Data reduction softwareXDS
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.10.1_2155))
Data quality characteristics
 Overall
Low resolution limit [Å]65.558
High resolution limit [Å]1.402
Rmerge0.041
Number of reflections77014
<I/σ(I)>18.4
Completeness [%]94.0
Redundancy6.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2980.2 M NaCl, 0.1 M sodium acetate pH 5.0, PEG 6000

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon