Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6AF7

DJ-1 C106S unbound

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE BL-5A
Synchrotron sitePhoton Factory
BeamlineBL-5A
Temperature [K]100
Detector technologyCCD
Collection date2013-04-17
DetectorADSC QUANTUM 315
Wavelength(s)1.000
Spacegroup nameP 31 2 1
Unit cell lengths74.750, 74.750, 75.420
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution26.600 - 1.300
R-factor0.10078
Rwork0.100
R-free0.12038
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1soa
RMSD bond length0.020
RMSD bond angle1.984
Data reduction softwareMOSFLM (7.0.9)
Data scaling softwareSCALA (3.3.20)
Phasing softwarePHASER (2.5.1)
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]26.6001.370
High resolution limit [Å]1.3001.300
Rmerge0.1030.354
Number of reflections60285
<I/σ(I)>10.14.2
Completeness [%]100.0100
Redundancy5.35.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293.15pH 8.5, 100mM TRIS-HCl, 200mM sodium citrate, 30% PEG 400, 5mM DTT

222624

PDB entries from 2024-07-17