Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6Z99

Copper transporter OprC

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2019-10-18
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)1.35132
Spacegroup nameC 2 2 21
Unit cell lengths154.644, 195.506, 165.629
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution84.180 - 2.680
R-factor0.2166
Rwork0.215
R-free0.25240
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6fok
RMSD bond length0.009
RMSD bond angle1.121
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (1.18_3855)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]84.1802.730
High resolution limit [Å]2.6802.680
Rpim0.056
Number of reflections704346894
<I/σ(I)>0.996
Completeness [%]99.9
Redundancy13.51
CC(1/2)0.575
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52930.2 M Choline chloride 0.1 M Tris 12-16 % w/v PEG 2000 MME

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon