Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6Z8S

Copper transporter OprC

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2020-02-09
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)1.351326
Spacegroup nameC 2 2 21
Unit cell lengths156.100, 195.690, 166.650
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution61.020 - 2.370
R-factor0.2203
Rwork0.219
R-free0.25170
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6fok
RMSD bond length0.008
RMSD bond angle0.988
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (1.18_3855)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]97.8502.410
High resolution limit [Å]2.3702.370
Rpim0.044
Number of reflections10318510239
<I/σ(I)>12.46
Completeness [%]100.0
Redundancy13.27
CC(1/2)0.315
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.52930.1 M NaCl 0.15 M NH4SO4 0.1 M MES 18-22% PEG1000 3 mM CuSO4

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon