6YLP
EGFP_in_Acidic_env Directionality of Optical Properties of Fluorescent Proteins
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-08-13 |
| Detector | DECTRIS PILATUS 300K |
| Wavelength(s) | 1.5419 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 50.970, 62.150, 68.790 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 46.120 - 1.550 |
| R-factor | 0.1776 |
| Rwork | 0.176 |
| R-free | 0.20660 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2y0g |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.720 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0103) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 46.120 | 46.120 | 1.590 |
| High resolution limit [Å] | 1.550 | 6.930 | 1.550 |
| Rmerge | 0.055 | 0.029 | 0.894 |
| Rmeas | 0.060 | 0.031 | 1.157 |
| Total number of observations | 353489 | ||
| Number of reflections | 61255 | 680 | 4560 |
| <I/σ(I)> | 16.94 | 65.52 | 1.03 |
| Completeness [%] | 99.9 | 99.3 | 99.9 |
| Redundancy | 5.771 | 8.941 | 2.49 |
| CC(1/2) | 0.999 | 1.000 | 0.373 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 3.8 | 298 | PEG 8000, potassium dihydrogen phosphate |