6XQ2
Human antibody S8V2-37 in complex with the influenza hemagglutinin head domain of A/Texas/50/2012(H3N2)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2018-10-23 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97910 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 294.800, 42.380, 155.760 |
Unit cell angles | 90.00, 111.50, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.059 | 3.110 |
High resolution limit [Å] | 3.002 | 3.002 |
Rmerge | 0.153 | 0.999 |
Rmeas | 0.175 | 1.140 |
Rpim | 0.083 | 0.538 |
Number of reflections | 36359 | 3560 |
<I/σ(I)> | 9.71 | 1.28 |
Completeness [%] | 98.3 | 98.09 |
Redundancy | 4.1 | 4.2 |
CC(1/2) | 0.994 | 0.791 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5 | 291.15 | 0.1 M magnesium sulfate, 20% w/v PEG4000, sodium acetate, pH 5.0 |