6XC9
Immune receptor complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-02-20 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.95370 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 65.993, 114.790, 153.926 |
Unit cell angles | 90.00, 90.07, 90.00 |
Refinement procedure
Resolution | 46.010 - 2.400 |
R-factor | 0.1863 |
Rwork | 0.184 |
R-free | 0.21870 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4z7u |
RMSD bond length | 0.003 |
RMSD bond angle | 0.622 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.15_3459) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.010 | 2.486 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.059 | 0.444 |
Rmeas | 0.628 | |
Rpim | 0.059 | 0.444 |
Number of reflections | 89707 | 8924 |
<I/σ(I)> | 8.82 | 2.13 |
Completeness [%] | 99.9 | 99.98 |
Redundancy | 2 | |
CC(1/2) | 0.996 | 0.667 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 13% PEG 8000, 0.2 M Potassium dihydrogen phosphate |