6X60
ClpP2 from Chlamydia trachomatis with resolved handle loop
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU FR-E SUPERBRIGHT |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2019-10-31 |
| Detector | RIGAKU RAXIS IV++ |
| Wavelength(s) | 1.54 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 129.710, 147.043, 97.059 |
| Unit cell angles | 90.00, 128.25, 90.00 |
Refinement procedure
| Resolution | 28.160 - 2.810 |
| R-factor | 0.2003 |
| Rwork | 0.198 |
| R-free | 0.23480 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4jct |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.18rc2_3794) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.870 |
| High resolution limit [Å] | 2.800 | 2.800 |
| Rmeas | 0.096 | 0.712 |
| Rpim | 0.049 | 0.374 |
| Number of reflections | 34843 | 2318 |
| <I/σ(I)> | 15.25 | 2.07 |
| Completeness [%] | 99.8 | |
| Redundancy | 3.8 | |
| CC(1/2) | 0.699 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 296 | Tacsimate pH 7 |