Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6WNH

Menin bound to inhibitor M-808

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2018-07-31
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.9787
Spacegroup nameI 41
Unit cell lengths153.549, 153.549, 81.283
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.560 - 2.100
R-factor0.193
Rwork0.191
R-free0.22800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3u84
RMSD bond length0.009
RMSD bond angle1.000
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareBUSTER (2.10.3)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.140
High resolution limit [Å]2.1002.100
Rmerge0.1022.550
Rmeas0.1102.864
Rpim0.0421.274
Number of reflections552302722
<I/σ(I)>5.9
Completeness [%]99.999
Redundancy6.94.9
CC(1/2)0.241
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.82771.96 M NaCl, 89 mM Bis-Tris pH 6.8, 0.178 M MgCl2 and 10.7 mM Pr Acetate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon