6V13
immune receptor complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-07-07 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9537 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 150.457, 56.766, 136.253 |
Unit cell angles | 90.00, 92.42, 90.00 |
Refinement procedure
Resolution | 45.380 - 2.750 |
R-factor | 0.2115 |
Rwork | 0.210 |
R-free | 0.24660 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6bil |
RMSD bond length | 0.012 |
RMSD bond angle | 0.943 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.380 | 2.900 |
High resolution limit [Å] | 2.750 | 2.750 |
Rmerge | 1.342 | |
Number of reflections | 30349 | 4424 |
<I/σ(I)> | 9.4 | |
Completeness [%] | 99.9 | |
Redundancy | 7 | |
CC(1/2) | 0.993 | 0.587 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2 M trisodium citrate, 20% PEG 3350 |