Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6UWA

Mouse PKC C1B and C2 domains

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]120
Detector technologyCCD
Collection date2012-02-23
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.94967
Spacegroup nameP 21 21 21
Unit cell lengths34.041, 58.974, 104.954
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution28.390 - 1.200
R-factor0.1348
Rwork0.134
R-free0.15340
Structure solution methodSAD
RMSD bond length0.007
RMSD bond angle1.083
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHENIX
Refinement softwarePHENIX (dev_3126)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.2031.214
High resolution limit [Å]1.2001.200
Rmerge0.1330.718
Rpim0.0540.348
Number of reflections1261773798
<I/σ(I)>12
Completeness [%]98.2
Redundancy5.3
CC(1/2)0.9960.658
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7289.1514% PEG 3350, 0.3 mM Lithium sulfate, 50 mM Ammonium citrate tribasic, 0.1 M HEPES pH 7.0

219869

PDB entries from 2024-05-15