6UPJ
HIV-2 PROTEASE/U99294 COMPLEX
Experimental procedure
| Source type | ROTATING ANODE |
| Source details | SIEMENS |
| Temperature [K] | 298 |
| Detector technology | AREA DETECTOR |
| Collection date | 1993-03-09 |
| Detector | SIEMENS |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 33.889, 45.675, 134.574 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 10.000 - 2.340 |
| R-factor | 0.161 * |
| Rwork | 0.161 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | EARLIER STRUCTURE FROM SAME LABORATORY |
| RMSD bond length | 0.016 |
| RMSD bond angle | 2.542 |
| Data reduction software | XENGEN |
| Data scaling software | XENGEN |
| Phasing software | MERLOT |
| Refinement software | CEDAR |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 10.000 | 2.490 |
| High resolution limit [Å] | 2.340 | 2.340 |
| Rmerge | 0.071 | 0.163 |
| Total number of observations | 27701 * | |
| Number of reflections | 7557 | |
| <I/σ(I)> | 11.9 | 4.37 |
| Completeness [%] | 81.0 | 38 |
| Redundancy | 3.7 | 2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | CRYSTALS WERE GROWN AT ROOM TEMPERATURE IN 4-7 UL HANGING DROPS OF EQUAL VOLUMES OF PROTEIN AT 8-10 MG/L AND WELL SOLUTION OF 30-35%(W/V) PEG 4000 IN 0.1 M HEPES AND PH RANGE 6.8 - 7.6., pH 7.0, vapor diffusion - hanging drop |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 8-10 (mg/ml) | |
| 2 | 1 | reservoir | PEG4000 | 30-35 (%(w/v)) | |
| 3 | 1 | reservoir | HEPES | 0.1 (M) | |
| 4 | 1 | reservoir | n-butanol | 1-3 (%) |