6UOQ
OsPYL/RCAR5 residues 24-29 solved from electron diffraction stills
Experimental procedure
| Source type | ELECTRON MICROSCOPE |
| Source details | TEAM1 |
| Temperature [K] | 100 |
| Detector technology | CMOS CAMERA |
| Collection date | 2019-04-04 |
| Detector | K2 IS |
| Wavelength(s) | 0.0197 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 4.720, 11.560, 39.190 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 7.474 - 1.007 |
| R-factor | 0.2358 |
| Rwork | 0.234 |
| R-free | 0.25570 |
| Data scaling software | XSCALE |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 7.474 | 7.474 | 1.200 |
| High resolution limit [Å] | 1.000 | 8.000 | 1.000 |
| Rmerge | 0.217 | 0.357 | |
| Rmeas | 0.266 | 0.440 | |
| Total number of observations | 2878 | ||
| Number of reflections | 1029 | 400 | |
| <I/σ(I)> | 2.87 | 1.8 | |
| Completeness [%] | 74.4 | 70.9 | |
| Redundancy | 2.797 | 2.685 | |
| CC(1/2) | 0.955 | 0.941 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | 10% ethanol |