6UIN
Role of Beta-hairpin motifs in the DNA duplex opening by the Rad4/XPC nucleotide excision repair complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Temperature [K] | 277 |
| Detector technology | CCD |
| Collection date | 2016-01-01 |
| Detector | MARMOSAIC 300 mm CCD |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 65 |
| Unit cell lengths | 77.665, 77.665, 264.054 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 38.833 - 3.348 |
| R-factor | 0.2141 |
| Rwork | 0.209 |
| R-free | 0.26230 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4yir |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.578 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.12_2829) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | |
| High resolution limit [Å] | 3.340 | 3.340 |
| Number of reflections | 12932 | |
| <I/σ(I)> | 19.1 | |
| Completeness [%] | 99.0 | |
| Redundancy | 6.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 277 | 50 mM BTP-HCl, 200 mM sodium chloride, 12% isopropanol, 100 mM calcium chloride |