Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6U9M

MLL1 SET N3861I/Q3867L bound to inhibitor 16 (TC-5109)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-G
Synchrotron siteAPS
Beamline21-ID-G
Temperature [K]100
Detector technologyCCD
Collection date2018-02-07
DetectorRAYONIX MX-300
Wavelength(s)0.9786
Spacegroup nameP 32
Unit cell lengths54.810, 54.810, 105.827
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.470 - 2.050
R-factor0.222
Rwork0.221
R-free0.25200
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5f5e
RMSD bond length0.010
RMSD bond angle1.060
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.090
High resolution limit [Å]2.0502.050
Number of reflections2230122301
<I/σ(I)>102
Completeness [%]100.0100
Redundancy7.87.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2772.2 M Sodium Malonate pH 7.0

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon