Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6TIU

DROSOPHILA GTP-TUBULIN Y222F MUTANT

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2018-11-28
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.98
Spacegroup nameP 21 21 21
Unit cell lengths65.970, 126.350, 249.790
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.000 - 3.571
R-factor0.222
Rwork0.221
R-free0.24410
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)3ryc
RMSD bond length0.008
RMSD bond angle0.980
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareBUSTER
Refinement softwareBUSTER (2.10.3 (3-OCT-2019))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.0003.790
High resolution limit [Å]3.5703.570
Number of reflections253043723
<I/σ(I)>4.150.92
Completeness [%]98.7
Redundancy11.7
CC(1/2)0.9970.565
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION293PEG1500, LISO4, PIPES BUFFER, PH 6.80

219869

PDB entries from 2024-05-15