6TIT
VSV G_440
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE BM30A |
Synchrotron site | ESRF |
Beamline | BM30A |
Temperature [K] | 93 |
Detector technology | PIXEL |
Collection date | 2018-10-15 |
Detector | DECTRIS PILATUS3 2M |
Wavelength(s) | 0.987 |
Spacegroup name | P 6 2 2 |
Unit cell lengths | 120.950, 120.950, 200.320 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 44.820 - 2.070 |
R-factor | 0.2083 |
Rwork | 0.207 |
R-free | 0.24170 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5i2s |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | PHENIX (1.17_3644) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.820 | 2.350 |
High resolution limit [Å] | 2.070 | 2.070 |
Number of reflections | 52870 | 6568 |
<I/σ(I)> | 8.27 | |
Completeness [%] | 99.5 | |
Redundancy | 6.8 | |
CC(1/2) | 0.900 | 0.396 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 8% PEG8000, 0.15M calcium acetate, 0.15M HEPES pH7.5 |