6TIT
VSV G_440
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE BM30A |
| Synchrotron site | ESRF |
| Beamline | BM30A |
| Temperature [K] | 93 |
| Detector technology | PIXEL |
| Collection date | 2018-10-15 |
| Detector | DECTRIS PILATUS3 2M |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 6 2 2 |
| Unit cell lengths | 120.950, 120.950, 200.320 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 44.820 - 2.070 |
| R-factor | 0.2083 |
| Rwork | 0.207 |
| R-free | 0.24170 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5i2s |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.17_3644) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.820 | 2.350 |
| High resolution limit [Å] | 2.070 | 2.070 |
| Number of reflections | 52870 | 6568 |
| <I/σ(I)> | 8.27 | |
| Completeness [%] | 99.5 | |
| Redundancy | 6.8 | |
| CC(1/2) | 0.900 | 0.396 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 8% PEG8000, 0.15M calcium acetate, 0.15M HEPES pH7.5 |