6TAF
Bd0314 DslA E154Q mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-07-27 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.97622 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 84.729, 47.854, 49.211 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.308 - 1.336 |
R-factor | 0.178 |
Rwork | 0.177 |
R-free | 0.19510 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | mutant protein |
RMSD bond length | 0.005 |
RMSD bond angle | 1.044 |
Data reduction software | XDS |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 100.000 | 1.380 |
High resolution limit [Å] | 1.336 | 1.370 |
Number of reflections | 45432 | 2267 |
<I/σ(I)> | 12.2 | |
Completeness [%] | 98.4 | |
Redundancy | 12.5 | |
CC(1/2) | 0.994 | 0.617 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 289 | 0.2M lithium sulphate 0.1M sodium citrate pH 5.5 20% PEG 3000 |