6T7V
KEAP1 IN COMPLEX WITH PEPTIDE 8
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2014-12-05 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1.00000 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 75.430, 75.430, 114.497 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 65.320 - 2.600 |
| R-factor | 0.2069 |
| Rwork | 0.202 |
| R-free | 0.27500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.133 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 65.320 | 2.810 |
| High resolution limit [Å] | 2.600 | 2.600 |
| Rmerge | 0.084 | 0.451 |
| Number of reflections | 11370 | 2311 |
| <I/σ(I)> | 17.77 | |
| Completeness [%] | 94.3 | 95.7 |
| Redundancy | 6.2 | 6.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277 | ammonium acetate |