6QY7

Human CSNK2A1 bound to ERB-041

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2015-09-13
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.97625
Spacegroup nameP 43 21 2
Unit cell lengths126.938, 126.938, 127.089
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution89.810 - 2.100
R-factor0.19807
Rwork0.196
R-free0.23538
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3pe1
RMSD bond length0.008
RMSD bond angle1.220
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0230)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]89.8102.150
High resolution limit [Å]2.1002.100
Rmerge0.0700.980
Number of reflections611304476
<I/σ(I)>14.41.9
Completeness [%]100.0100
Redundancy87
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.527710% PEG6000, 2M sodium chloride

220113

PDB entries from 2024-05-22