6QPH

Dunaliella minimal PSI complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]80
Detector technologyPIXEL
Collection date2017-07-08
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.999
Spacegroup nameP 1 21 1
Unit cell lengths158.881, 100.506, 191.040
Unit cell angles90.00, 91.73, 90.00
Refinement procedure
Resolution48.947 - 3.400
R-factor0.3377
Rwork0.337
R-free0.35630
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5l8r
RMSD bond length0.008
RMSD bond angle1.876
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX ((1.15.2_3472: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.9473.500
High resolution limit [Å]3.4003.400
Rpim0.0800.636
Number of reflections832504575
<I/σ(I)>8.2
Completeness [%]99.9
Redundancy8.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.5277Sodium cacodylate 50mM, MgCl2 100mM, PEG1500 8-11%

219869