Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6Q8R

HEW Lysozyme under 2 kbar of argon

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID30B
Synchrotron siteESRF
BeamlineID30B
Temperature [K]100
Detector technologyPIXEL
Collection date2018-07-27
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.7712
Spacegroup nameP 43 21 2
Unit cell lengths77.830, 77.830, 37.990
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.950 - 1.700
R-factor0.15445
Rwork0.153
R-free0.18798
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)5fst
RMSD bond length0.010
RMSD bond angle1.690
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareFFT
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.0001.780
High resolution limit [Å]1.7001.700
Rmeas0.0830.472
Number of reflections12830930
<I/σ(I)>19.032.4
Completeness [%]94.458.3
Redundancy188.5
CC(1/2)0.9990.887
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.829810 % (W/V) NACL, 0.1 M ACETATE BUFFER PH 4.8. + 25 % (V/V) ETH-GLYCOL

231029

PDB entries from 2025-02-05

PDB statisticsPDBj update infoContact PDBjnumon