6Q39
Complex of Arginase 2 with Example 49
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-01-08 |
Detector | RIGAKU SATURN 944 |
Wavelength(s) | 1.54178 |
Spacegroup name | P 42 21 2 |
Unit cell lengths | 128.303, 128.303, 159.155 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.912 - 2.213 |
R-factor | 0.1647 |
Rwork | 0.162 |
R-free | 0.20980 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1d3v |
RMSD bond length | 0.008 |
RMSD bond angle | 1.105 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | PHENIX (1.11.1_2575) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.280 |
High resolution limit [Å] | 2.200 | 2.210 |
Rmerge | 0.126 | 0.447 |
Total number of observations | 589289 | |
Number of reflections | 61688 | 6783 |
<I/σ(I)> | 16.1 | 4.7 |
Completeness [%] | 91.3 | 55.4 |
Redundancy | 9.6 | 8.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | CRYSTALS IN CONDITION H3 FROM SILVER BULLET SCREEN (HAMPTON RESEARCH) USING TACSIMATE IN THE |