Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6Q0I

Inferred intermediate I-7 (I-7-6) of the human antibody lineage 652 in complex with influenza hemagglutinin head domain of A/Beijing/262/95(H1N1)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]80
Detector technologyCCD
Collection date2018-06-20
DetectorADSC QUANTUM 315r
Wavelength(s)1.0000
Spacegroup nameP 21 21 21
Unit cell lengths51.950, 70.410, 203.740
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.881 - 2.702
R-factor0.2156
Rwork0.213
R-free0.25540
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.8812.799
High resolution limit [Å]2.7022.702
Rmerge0.0721.038
Number of reflections2127918093
<I/σ(I)>24.15
Completeness [%]99.899.23
Redundancy8.7
CC(1/2)0.9990.896
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP9291.15100mM lithium sulfate, 30% (w/v) PEG 6000, 100mM CHES

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon