6PYK

P. mirabilis hemolysin A mutant - F80L

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2015-06-20
DetectorRAYONIX MX-225
Wavelength(s)0.97872
Spacegroup nameP 1 2 1
Unit cell lengths51.550, 34.011, 59.480
Unit cell angles90.00, 101.02, 90.00
Refinement procedure
Resolution34.011 - 1.350
R-factor0.1344
Rwork0.133
R-free0.16150
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3fy3
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.15_3459)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.0111.390
High resolution limit [Å]1.3501.350
Rmerge0.0850.804
Rpim0.0340.331
Number of reflections445784273
<I/σ(I)>15.92.1
Completeness [%]99.395.1
Redundancy7.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5298PEG 4000

219869