6PL1

TRK-A IN COMPLEX WITH LIGAND 1B

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2015-11-15
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0
Spacegroup nameP 31 1 2
Unit cell lengths51.915, 51.915, 229.322
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.000 - 2.030
R-factor0.22008
Rwork0.217
R-free0.26029
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.293
Data reduction softwareXDS
Data scaling softwareXSCALE
Refinement softwareREFMAC (5.8.0049)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]76.4402.270
High resolution limit [Å]2.0302.030
Rmerge0.0320.441
Number of reflections23189
<I/σ(I)>22.51
Completeness [%]97.495.1
Redundancy3.63.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP277.1520mM Tris/HCl, pH=8.5, 50mM NaCl, 2mM DTT, 0.5mM PMSF

229380