6PDQ
Ancestral Effector Caspase 3/6/7
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-BM |
Synchrotron site | APS |
Beamline | 22-BM |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-06-14 |
Detector | MAR CCD 130 mm |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 52.169, 78.760, 107.744 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.493 - 1.830 |
R-factor | 0.1935 |
Rwork | 0.191 |
R-free | 0.23390 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.807 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.15.2_3472: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.493 | 1.890 |
High resolution limit [Å] | 1.830 | 1.830 |
Number of reflections | 39730 | 3741 |
<I/σ(I)> | 8.5 | |
Completeness [%] | 99.2 | |
Redundancy | 7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 0.2 M ammonium acetate, pH 4.6, 0.1 M sodium acetate trihydrate, 30% PEG 4000 |