6PA1
Killer cell immunoglobulin-like receptor 2DL2 in complex with HLA-C*07:02
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-10-12 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.954 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 68.565, 82.086, 104.887 |
Unit cell angles | 90.00, 90.12, 90.00 |
Refinement procedure
Resolution | 32.321 - 3.010 |
R-factor | 0.2655 |
Rwork | 0.263 |
R-free | 0.30960 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1efx |
RMSD bond length | 0.002 |
RMSD bond angle | 0.711 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.120 |
High resolution limit [Å] | 3.000 | 3.000 |
Number of reflections | 20697 | 2015 |
<I/σ(I)> | 4.6 | |
Completeness [%] | 97.0 | 90.5 |
Redundancy | 4 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2 M Sodium tartrate dibasic dihydrate and 20% w/v PEG 3350 |