6OSH
Potent and Selective Antitumor Antibody Targeting a Membrane-Proximal Epitope of ROR2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-F |
| Synchrotron site | APS |
| Beamline | 21-ID-F |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-11-20 |
| Detector | MARMOSAIC 225 mm CCD |
| Wavelength(s) | 0.978720 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 45.165, 67.201, 89.610 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 40.332 - 1.117 |
| R-factor | 0.1622 |
| Rwork | 0.162 |
| R-free | 0.16920 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6ba5 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.983 |
| Data reduction software | XDS |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.15.2_3472: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.330 | 1.157 |
| High resolution limit [Å] | 1.117 | 1.117 |
| Rmerge | 0.045 | 0.561 |
| Rmeas | 0.050 | 0.756 |
| Rpim | 0.022 | 0.502 |
| Number of reflections | 81433 | 4074 |
| <I/σ(I)> | 17.3 | |
| Completeness [%] | 89.0 | |
| Redundancy | 4.9 | |
| CC(1/2) | 0.999 | 0.530 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 294 | 0.2 M Na citrate tribasic 20% PEG3350 |