Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6OMN

Glycosylated BMP2 homodimer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2010-04-22
DetectorDECTRIS PILATUS 300K
Wavelength(s)1
Spacegroup nameP 31
Unit cell lengths62.743, 62.743, 126.350
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution41.200 - 2.680
R-factor0.1786
Rwork0.175
R-free0.24320
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.290
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Refinement softwareBUSTER (2.11.1)
Data quality characteristics
 Overall
Low resolution limit [Å]41.200
High resolution limit [Å]2.680
Number of reflections15473
<I/σ(I)>5
Completeness [%]98.9
Redundancy4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293100mM TrisHCl pH 8.5, 100mM NaCl, 12% MPD

219869

PDB entries from 2024-05-15