Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6OLY

Full-length MthK channel at 3.1 angstrom resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]93
Detector technologyCCD
Collection date2006-01-01
DetectorADSC QUANTUM 315r
Wavelength(s)1.0
Spacegroup nameP 61 2 2
Unit cell lengths137.456, 137.456, 373.026
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution39.702 - 3.112
R-factor0.2376
Rwork0.236
R-free0.27460
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3rbz
RMSD bond length0.006
RMSD bond angle0.904
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((dev_3374: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.7023.223
High resolution limit [Å]3.1123.112
Rmerge0.134
Rpim0.038
Number of reflections377853251
<I/σ(I)>25.41.9
Completeness [%]98.2
Redundancy11.6
CC(1/2)0.489
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP30028% PEG350-MME, 0.1M MES pH 6.5, 0.2 M CaCl2