Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6O2F

GCN4 with NPEG4 at position 18

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsENRAF-NONIUS FR591
Temperature [K]293
Detector technologyCCD
Collection date2018-03-29
DetectorAPEX II CCD
Wavelength(s)1.55
Spacegroup nameI 21 21 21
Unit cell lengths19.249, 30.046, 106.834
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution28.924 - 1.800
R-factor0.1858
Rwork0.180
R-free0.23510
Data reduction softwarePROTEUM PLUS
Data scaling softwarePROTEUM PLUS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 Overall
Low resolution limit [Å]28.924
High resolution limit [Å]1.800
Number of reflections3133
<I/σ(I)>11.9
Completeness [%]99.7
Redundancy9.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293Pact Premier B1

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon