Pleurotus ostreatus OstreolysinA mutant E69A with Bis-Tris

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-19
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.97903
Spacegroup nameC 1 2 1
Unit cell lengths69.857, 86.684, 92.878
Unit cell angles90.00, 99.13, 90.00
Refinement procedure
Resolution49.265 - 1.800
R-factor0.1952
Rwork0.194
R-free0.21900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4ov8
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.12_2829))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.830
High resolution limit [Å]1.8004.8801.800
Rmerge0.0390.0240.438
Rmeas0.0430.0270.499
Rpim0.0180.0110.233
Number of reflections4739925521701
<I/σ(I)>9.6
Completeness [%]93.497.768.4
Redundancy5.25.73.9
CC(1/2)0.9990.888
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.52930.1 M Bis-Tris, 0.125 M lithium sulfate, 25% (w/v) PEG3350, 25% ethylene glycol

219869

PDB entries from 2024-05-15