Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HYW

THE GLIC PENTAMERIC LIGAND-GATED ION CHANNEL MUTANT Y119F

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID30B
Synchrotron siteESRF
BeamlineID30B
Temperature [K]193
Detector technologyPIXEL
Collection date2016-10-28
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9771
Spacegroup nameC 1 2 1
Unit cell lengths183.000, 132.240, 161.480
Unit cell angles90.00, 103.25, 90.00
Refinement procedure
Resolution20.000 - 2.800
R-factor0.193
Rwork0.192
R-free0.21200
RMSD bond length0.010
RMSD bond angle1.070
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.3402.850
High resolution limit [Å]2.8002.800
Number of reflections85783
<I/σ(I)>9.9
Completeness [%]93.2
Redundancy2.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION29112-14.5% PEG4K; 15% GLycerol; 400 mM NaSCN; 3% DMSO; 100mM NaAcetate pH 4.

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon