Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HYA

THE GLIC PENTAMERIC LIGAND-GATED ION CHANNEL MUTANT Q193L

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]193
Detector technologyCCD
Collection date2015-10-11
DetectorADSC QUANTUM 315r
Wavelength(s)0.9789
Spacegroup nameC 1 2 1
Unit cell lengths181.240, 133.320, 157.720
Unit cell angles90.00, 100.96, 90.00
Refinement procedure
Resolution20.000 - 3.390
R-factor0.1852
Rwork0.184
R-free0.21240
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.120
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareBUSTER
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.8403.500
High resolution limit [Å]3.3903.390
Rmerge0.0650.406
Number of reflections50723
<I/σ(I)>4.91.4
Completeness [%]99.192.6
Redundancy3.23.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION4293PH 4, VAPOR DIFFUSION, TEMPERATURE 293K;12-14.5% PEG4K; 15% GLycerol; 400 mM NaSCN; 3% DMSO; 100mM NaAcetate pH 4.

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon