Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HY9

THE GLIC PENTAMERIC LIGAND-GATED ION CHANNEL MUTANT Q193M

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]193
Detector technologyCCD
Collection date2015-10-04
DetectorADSC QUANTUM 315r
Wavelength(s)0.9789
Spacegroup nameC 1 2 1
Unit cell lengths181.990, 134.360, 159.180
Unit cell angles90.00, 101.47, 90.00
Refinement procedure
Resolution20.000 - 2.950
R-factor0.204
Rwork0.203
R-free0.22650
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.100
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareBUSTER
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.4003.010
High resolution limit [Å]2.9502.950
Rmerge0.064
Number of reflections76643
<I/σ(I)>11.7
Completeness [%]97.095.6
Redundancy43.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION4291PH 4, VAPOR DIFFUSION, TEMPERATURE 291K. 12-14.5% PEG4K; 15% GLycerol; 400 mM NaSCN; 3% DMSO; 100mM NaAcetate pH 4.