Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HS0

EthR2 in complex with compound 5 (BDM71847)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-1
Synchrotron siteESRF
BeamlineMASSIF-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-10-27
DetectorDECTRIS PILATUS3 2M
Wavelength(s)1.0
Spacegroup nameC 1 2 1
Unit cell lengths110.090, 40.560, 108.740
Unit cell angles90.00, 96.75, 90.00
Refinement procedure
Resolution107.990 - 1.450
R-factor0.19848
Rwork0.197
R-free0.21732
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5n7o
RMSD bond length0.012
RMSD bond angle1.799
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0232)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]107.9901.480
High resolution limit [Å]1.4501.450
Rmeas0.0450.570
Number of reflections807734071
<I/σ(I)>13.952.23
Completeness [%]95.498.3
Redundancy2.72.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.2-0.4M ammonium chloride, 0.1M MES, 20% (W/V) PEG600

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon