Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6HR0

Optimizing electroactive organisms: the effect of orthologous proteins

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2016-06-30
DetectorPSI PILATUS 6M
Wavelength(s)0.97950
Spacegroup nameP 43 21 2
Unit cell lengths66.171, 66.171, 43.236
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.270 - 1.040
Rwork0.152
R-free0.17780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1m1p
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwarePHENIX ((1.14_3260: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]26.2701.070
High resolution limit [Å]1.0401.040
Number of reflections448362412
<I/σ(I)>14.2
Completeness [%]96.1
Redundancy6.7
CC(1/2)0.9900.386
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293.150.1 M Bicine pH 8.5 and 3.7 M Ammonium Sulfate

219869

PDB entries from 2024-05-15