Human STK10 bound to BIRB-796

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-20
DetectorDECTRIS PILATUS3 R CdTe 300K
Wavelength(s)0.9282
Spacegroup nameP 64 2 2
Unit cell lengths100.667, 100.667, 145.786
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution87.180 - 2.250
R-factor0.24358
Rwork0.240
R-free0.30104
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4use
RMSD bond length0.006
RMSD bond angle1.111
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0222)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]87.1802.320
High resolution limit [Å]2.2502.250
Rmerge0.070
Number of reflections214221920
<I/σ(I)>22.82.1
Completeness [%]100.0100
Redundancy17.718.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP627720% PEG6000, 10% ethylene glycol, 0.1M MES pH 6.0, 0.1M magnesium chloride

219869