6FK1
Cyclophilin A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-02-18 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.98005 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 61.717, 61.717, 93.130 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 46.357 - 1.299 |
R-factor | 0.1636 |
Rwork | 0.163 |
R-free | 0.18110 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2cpl |
RMSD bond length | 0.014 |
RMSD bond angle | 1.372 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.360 | 1.346 |
High resolution limit [Å] | 1.299 | 1.299 |
Rmerge | 0.043 | |
Rmeas | 0.045 | |
Rpim | 0.014 | 0.662 |
Number of reflections | 51157 | 5010 |
<I/σ(I)> | 24.47 | 0.79 |
Completeness [%] | 99.9 | 98.89 |
Redundancy | 10.9 | 10.7 |
CC(1/2) | 1.000 | 0.392 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 3.5M Sodium formate |