Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6EU6

Sensor Amt Protein

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2015-02-04
DetectorPSI PILATUS 6M
Wavelength(s)1.000
Spacegroup nameP 63
Unit cell lengths99.745, 99.745, 89.069
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution86.380 - 1.980
R-factor0.15356
Rwork0.152
R-free0.18450
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2b2h
RMSD bond length0.019
RMSD bond angle1.964
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]86.3802.030
High resolution limit [Å]1.9801.980
Rmerge0.1121.461
Rpim0.0370.469
Number of reflections334012466
<I/σ(I)>12.1
Completeness [%]100.099.9
Redundancy10.310.5
CC(1/2)0.9990.735
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP72930.1 M MES/NaOH pH 7.0 24 % (w/v) of polyethylene glycol 3350

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon