6CYN
CTX-M-14 N106S/D240G mutant
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.2 |
| Synchrotron site | ALS |
| Beamline | 8.2.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-10-19 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.999989 |
| Spacegroup name | P 32 |
| Unit cell lengths | 83.238, 83.238, 231.982 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 34.420 - 1.600 |
| R-factor | 0.169 |
| Rwork | 0.168 |
| R-free | 0.20400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ylt |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.810 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((DEV_3071: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.830 |
| High resolution limit [Å] | 1.600 | 1.800 |
| Rmerge | 0.119 | 0.662 |
| Number of reflections | 235349 | |
| <I/σ(I)> | 14.2 | |
| Completeness [%] | 99.4 | |
| Redundancy | 6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6 | 296 | 25% PEG 1500 (w/v), 0.1 M PCB buffer, pH 6.0 |