Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6CYN

CTX-M-14 N106S/D240G mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]100
Detector technologyCCD
Collection date2014-10-19
DetectorADSC QUANTUM 315r
Wavelength(s)0.999989
Spacegroup nameP 32
Unit cell lengths83.238, 83.238, 231.982
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution34.420 - 1.600
R-factor0.169
Rwork0.168
R-free0.20400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ylt
RMSD bond length0.006
RMSD bond angle0.810
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((DEV_3071: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.830
High resolution limit [Å]1.6001.800
Rmerge0.1190.662
Number of reflections235349
<I/σ(I)>14.2
Completeness [%]99.4
Redundancy6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP629625% PEG 1500 (w/v), 0.1 M PCB buffer, pH 6.0

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon